Roof Space Assessment
Is Your Roof Space Suitable for Ducted Air Con?
The roof space decides more about a retrofit than any other factor. During the inspection we look at:
| What we check | Why it matters |
|---|---|
| Clearance and pitch | The indoor unit typically needs around 400–600 mm of height plus room to service it |
| Ceiling joists and trusses | Ducts are routed between or over them without cutting structural timber |
| Access path | The unit has to fit through the manhole or be brought in another way |
| Insulation and wiring | Batts are moved and replaced, and old cabling is kept clear of the ducts |
| Raked or flat sections | Rooms without roof space above may need wall outlets or a bulkhead |
Most Perth tile and metal roofs on single-storey homes have plenty of room. Where space is tight, a slimline indoor unit or a different unit location usually solves it. Our ducted air conditioning installation team will tell you honestly if ducted is not the right fit.


Return Air Design
Why the Return Air Grille Matters So Much
The return air grille is where the system draws air back from the house. Get it wrong and a ducted retrofit can be noisy, inefficient or uneven, even with the right size unit. In existing homes we look at:
- Location – usually a central hallway or open living area, so air can flow back from every zone.
- Size – a grille that is too small makes the system whistle and work harder.
- Distance from bedrooms – keeping it away from bedroom doors reduces noise at night.
- Filter access – it needs to be easy to reach, because the filter behind it is the one you clean.
Larger or long homes sometimes need two return air grilles. We also check that internal doors have enough gap underneath, or add transfer grilles, so closed bedrooms still breathe properly.
Retrofit Inclusions
What Your Ducted Air Con Installation Includes
Every retrofit we complete includes:
- Roof space inspection – clearance, access, structure and insulation checked before you get a quote.
- Outlet and return air layout – a plan showing where each ceiling outlet and grille will go, room by room.
- Insulated ductwork – correctly sized flexible ducts with a main trunk, routed clear of trusses and wiring.
- Careful ceiling work – neat cuts in existing plaster, sealed outlets and minimal patching.
- Insulation put back – roof batts moved for the install are replaced around the new ducts.
- Commissioning and balancing – airflow adjusted so each room gets its share, then a full handover.


Retrofit Pricing Guide
How Much Does a Ducted Air Con Installation Cost?
A ducted air con installation in an established Perth home generally costs $9,000–$20,000+, with most 3–4 bedroom retrofits between $11,000 and $16,000. Zoning typically adds about $1,000–$3,000. Retrofits vary more than new builds because of what we find in the roof:
| Retrofit factor | Effect on price |
|---|---|
| Tight roof clearance | More labour, or a slimline unit |
| Extensions and raked ceilings | Extra duct runs, wall outlets or bulkheads |
| Number of outlets | Each outlet adds a duct run and a ceiling cut |
| Switchboard condition | Older boards may need an upgrade first |
| Removing an old system | Disposal and making good add to the job |
How A Retrofit Works
Four Steps to Retrofitting Ducted Air Con
Adding ducted air con to an existing home follows four clear steps:
- Roof and room inspection – we go into the roof, measure each room and note anything that affects duct routes.
- Layout and quote – you see the proposed outlet, return air and unit positions with an itemised price.
- Installation – the unit, ducts, outlets, pipework and electrical are installed, usually over two to three days.
- Balancing and handover – we adjust airflow room by room, set up zones and show you how it all works.


Outlet Placement
Getting Outlets Right in Older and Extended Homes
Outlet placement is what you feel every day. In a retrofit we place each outlet to suit how the room is used, not just where the ceiling is easiest to cut.
Bedrooms – outlets go away from the bed head so cool air does not blow straight onto sleepers.
Open-plan living – two or more outlets spread across the space, with extra capacity near west-facing glass.
Extensions and patios enclosed later – these often have flat or raked ceilings with no roof space, so we may use a wall outlet, a short bulkhead or a separate split.
Two-storey homes – upstairs rooms can be fed through cupboards or wall cavities, or by a second system.
Heritage and character homes – we choose outlet styles and positions that suit ornate ceilings and cornices.
If your home has asbestos-containing materials, which is common in houses built before 1990, we will discuss safe ways to work around them before quoting.
Related Ducted Services
More Help With Your Ducted Project
These pages cover the other parts of a ducted project, from installation day to choosing an installer, plus local pages for nearby suburbs:
- What happens on installation day
- Choosing a ducted installer
- Perth roof types and ducted
- Air conditioner maintenance
- Nedlands
- Claremont
- Dianella
- Morley
Prefer the big picture? Visit our main ducted air conditioning installation page.

Frequently Asked Questions About Ducted Air Con Installation
Retrofitting Ducted Air Con: Your Questions Answered
Yes. Ducted air con installation works in most established Perth homes because the indoor unit and ducts sit in the roof space. We inspect the roof first to confirm there is enough clearance and a practical route to each room.
The indoor unit generally needs roughly 400–600 mm of height plus access to service it. Most single-storey tile and metal roofs have enough room, and slimline units suit tighter spaces.
Raked ceilings, flat-roofed extensions and enclosed patios can be served with wall outlets, a short bulkhead, or a separate split system for that room.
Usually in a central hallway or open living area, away from bedroom doors. It needs to be big enough to stop whistling and easy to reach for filter cleaning.
Yes, but only for each outlet and the return air grille. Cuts are made neatly to fit the fittings, so there is normally little or no patching needed.
It should not be. Noise usually comes from undersized ducts, a cramped return air grille or an outdoor unit beside a bedroom window. Correct duct sizing and careful placement keep a retrofit quiet at night.
We move batts where we need to work and put them back around the new ducts. If your insulation is old or patchy, we will let you know so you can consider topping it up.
Most retrofits take two to three days. Tight roofs, two-storey homes or extra outlet work can add a day, which we confirm after the inspection.
